[AIR-CR] How do I connect Motion Detector Request-To-Exit (RTE)?

[AIR-CR] How do I connect Motion Detector Request-To-Exit (RTE)?

Use the wiring example shown in the figure below.
  1. Connect the wires coming from the PIR Request to Exit motion sensor relay to GND (black wire) and EXIT (blue wire) on the controller.
  2. If the wires from the motion sensor relay are connected to the COM and NO (normally open) terminals, set the CLOSE condition in the controller settings.
  3. If the wires from the motion sensor relay are connected to the COM and NC (normally closed) terminals, set the OPEN condition in the controller settings.
  4. If the correct condition corresponding to the connection type is set, the controller output will be activated when motion is detected and not after the motion ends.


    • Related Articles

    • [ICON-Pro] How do I connect Motion Detector Request-To-Exit (RTE)?

      Use the wiring example shown in the figure below. Connect the wires coming from the PIR Request to Exit motion sensor control relays to the free GND and REX terminals on the controller. If the wires from the motion sensor relays are connected to the ...
    • [AIR-CR] How do I connect Ethernet?

      To connect the AIR-CR device to the Internet via Ethernet, follow these steps: Prepare Ethernet Cable: If not already done, strip the Ethernet cable to expose the individual wires. Connect Ethernet Wires: Match the colors of the Ethernet wires to the ...
    • [AIR-CR] How do I connect Exit Button and Door Sensor?

      Use the wiring example shown in the figure below. Connect the wires coming from the exit button to GND (black wire) and EXIT (blue wire). Connect the wires coming from the door sensor to GND (black wire) and DPS (pink wire). If the wires on the ...
    • [AIR-CR] How do I connect an Electric Lock?

      Use the connection example shown in the figure below.
    • [AIR-CR] How do I connect a Reader?

      Connecting a reader to the Wiegand interface. Use the connection example shown in the figure below: Connection of the reader to RS-485 interface via OSDP protocol. Use the connection example shown in the figure below: